Quote
Quote Cart
clear all items

Carbon Steel York Steam Boiler - IPP# 248858

  • Carbon Steel York Steam Boiler - IPP# 248858 Carbon Steel York Steam Boiler - IPP# 248858
  • Carbon Steel York Steam Boiler - IPP# 248858
Overview
Boiler
Steam
York
Used
Carbon Steel
Other Specifications
373 kW (500 HP)
Capacity
7,824 kg/h (17,250 lb/h)

500 HP 1985

Similar Equipment

Carbon Steel York Steam Boiler

Type: Boiler

Subtype: Steam

Manufacturer: York

Condition: Used

Material: Carbon Steel

Power: 373 kW (500 HP)

Capacity (Design): 7,824 kg/h (17,250 lb/h)

500 HP

Carbon Steel Ansaldo Volund Steam Boiler

Type: Boiler

Subtype: Steam

Manufacturer: Ansaldo Volund

Condition: Used

Material: Carbon Steel

Boiler Type: Water Tube

Temperature: 105 °C (221 °F)

normal working pressure 83 bara,
flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or gas oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, energy input 13.1 MW, fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78sqm, total 881sqm
the boiler is an all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces,
boiler includes:
(1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends,
(1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar,
(1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara
(3) Feed water pumps, manufactured by KSB, type HGM-2/15,
Other associated equipment include fans, valves, pumps, instruments, control panels, etc

Power: 13,100 kW (17,567 HP). Capacity (Design): 19,958 kg/h (44,000 lb/h). Fuel Type: Natural Gas. Pressure: 91 bar (1,320 psi). Controls: Yes. Burner Manufacturer: Saacke. Low NOx: Yes. Deaerator System: Yes.

Carbon Steel Ansaldo Volund Steam Boiler

Type: Boiler

Subtype: Steam

Manufacturer: Ansaldo Volund

Condition: Used

Material: Carbon Steel

Boiler Type: Water Tube

Temperature: 297 °C (567 °F)

and gas oil fired
energy input 13.1 MW
fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr,
heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78 SqM, total 881 SqM.
2 x 20 t/hr boilers working in tandem, the boilers are all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, final condensing (Ceecon) economiser which preheats the boiler feed water.
Main item consists of:
(2) 20 t/hr (design load, 100% Maximum Continuous Rating) Ansaldo Volund water tube boilers, design pressure 91 bara, normal working pressure 83 bara, feed water temperature 105 deg C, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr,
(1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends,
(1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar,
(1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara
(3) Feed water pumps, manufactured by KSB, type HGM-2/15,
Other associated equipment include fans, valves, pumps, instruments, control panels, platform between boilers, etc

Power: 13,100 kW (17,567 HP). Capacity (Design): 40,370 kg/h (89,000 lb/h). Fuel Type: Natural Gas. Pressure: 80 bar (1,160 psi). Controls: Yes. Burner Manufacturer: Saacke. Deaerator System: Yes.

Steam Boiler

Type: Boiler

Subtype: Steam

Manufacturer: Cleaver Brooks

Model: CFH-700-70HP-150#ST

Condition: Used

Material: Carbon Steel

Boiler Type: Firetube

Temperature: 100 °C (212 °F)

Power: 52.2 kW (70 HP). Capacity (Design): 1,095 kg/h (2,415 lb/h). Capacity Working: 1,296 kg/h (2,857 lb/h). Fuel Type: Natural Gas. Pressure: 10.3 bar (150 psi). Controls: Yes. Deaerator System: Yes.