Quote
Quote Cart
clear all items

Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022

  • Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022 Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022
  • Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022 Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022
  • Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022
  • Kohler 40REOZJB 40KW Diesel Electric Power Generator - IPP# 247022
Overview
Power Generator
Kohler
40REOZJB
Used
Carbon Steel
Capacity
0.04 MW
Other Specifications
154 amp
240
3
3
Yes
285.4
Diesel
Direct Coupled
Engine
John Deere
3029TF150
48
Yes
Yes
Yes
Yes
Yes
Yes
50
.8
Yes
Yes
Yes
Drive
35.8 kW (48 HP)
3
Dimensions
2,000 mm (78.7 in)
1,050 mm (40.9 in)
1,250 mm (50.2 in)

400KW 70-79hp @ 2500RPM600V max @ 48A, 50kVA, 60Hz, Line to Line Voltage

Similar Equipment

0.15 MW Carbon Steel Power Generator

Type: Power Generator

Manufacturer: Kohler

Model: 150R0XJ71

Condition: Used

Material: Carbon Steel

Capacity: 0.15 MW

Amperage: 600 amp

150KW Diesel backup generator. manufactured by Kohler

Voltage: 240. Cycle: 60. Phase: 3. Emergency: Yes. Operational Hours: 8,293. Drive Power: 150 kW (201.2 HP). Fuel Type: Diesel. Power Transmission: Direct Coupled. Batteries: Yes. Battery Charger: Yes. Controls: Yes.

Carbon Steel Power Generator

Type: Power Generator

Manufacturer: Dorman

Condition: Used

Material: Carbon Steel

Capacity: 0.19 MW

Voltage: 400

diesel engine driven electric generator. Unit rated 187.5 KW, 3/50/230/400 volt, 1500 rpm. Driven by (6) cylinders. Diesel engine, Type GLET-CA-2, SN 06042/1175/040. Turbo charged, oil and water cooling system. Unit w/built-in control panel. Skid mtd.

Cycle: 50. Phase: 3. Drive Power: 187.5 kW (251.4 HP). Fuel Type: Diesel. Powered By: Engine. Controls: Yes.

Carbon Steel Waukesha 16VAT27GL Power Generator

Type: Power Generator

Manufacturer: Waukesha

Model: 16VAT27GL

Condition: Used

Material: Carbon Steel

Capacity: 3.4 MW

Amperage: 220.5 amp

SAA #2000-168, natural gas fired, continuous, comp ratio 9/1, min.WKI 91, ignition timing (BTDC) 11-02, service 4650 HP (3469 Kw), altitude limit 500 feet (152 meter), governed speed 1000 rpm, 0.80mm valve intake & exhaust clearance, firing order 1R-1L-4R-4L-7R-7L-6R-6L-8R-8L-5R-5L-2R-2L-3R-3L, AC generator (alternator) manufactured by Leroy Somer, type LSA-56-BM65-6P, serial #167056-2, IP 23, 3360.8 Kw, 4201 kVA power rating, 11000 volt, 220.5 Amp, 3 phase, 50 Hz, 1000 rpm, excitation AREP, all mounted on a carbon steel skid.

Voltage: 11,000. Cycle: 50. Phase: 3. Operational Hours: 34,000. Drive Power: 3,350 kW (4,500 HP). Fuel Type: Natural Gas. Powered By: Engine.

Carbon Steel Waukesha 16VAT27GL Power Generator

Type: Power Generator

Manufacturer: Waukesha

Model: 16VAT27GL

Condition: Used

Material: Carbon Steel

Capacity: 6.7 MW

Amperage: 220.5 amp

gas fired combined heat and power system, system includes: 5000 kg/hr Cochran single pass waste heat recovery boiler, max continuous 5010kg/hr, serial #95/2766, manufactured by Cochran Boilers Limited,design pressure 13 barg, inlet temperature 430 degrees C, design saturated steam temperature 188 degrees C (@ 10.5 barg), safety valve setting 11.55 barg, heat transfer duty 2934 +- 15%, specific garavity/density 0.95 kg/m3, specific heat 1.00 kCal/kg.C, approximate boiler dimensions 2630mm diameter x 6m long, boiler an with economiser, manufactured by Flametec ltd, serial #35690/04068, design pressure 20 barg @ 160 degrees C, 2 x 3360.8 Kw (4201 kVA) gas engine driven electrical generator, engine manufactured by Waukesha (Dresser), model #16VAT27GL, serial #C-80859/1 & C-80859/2, SAA #2000-168, natural gas fired, continuous, comp ratio 9/1, min.WKI 91, ignition timing (BTDC) 11-02, service 4650 HP (3469 Kw), altitude limit 500 feet (152 meter), governed speed 1000 rpm, 0.80mm valve intake & exhaust clearance, firing order 1R-1L-4R-4L-7R-7L-6R-6L-8R-8L-5R-5L-2R-2L-3R-3L, AC generator (alternator) manufactured by Leroy Somer, type LSA-56-BM65-6P, serial #167056-2, IP 23, 3360.8 Kw, 4201 kVA power rating, 11000 volt, 220.5 Amp, 3 phase, 50 Hz, 1000 rpm, excitation AREP, all mounted on a carbon steel skid oil lubrication, cooling water system, MCC control panels, some ductwork, process description: natural gas is used to fuel two gas engine powered generator sets that provide electrical power to the site, with the ability to export surplus power to the grid, heat extraction from the exhaust gases is used within the heat recovery system to heat the boiler feed water to the steam boiler, which provides steam to the plant steam main, excess heat from each engines jacket water cooling system and intercooler cooling system is removed and dispersed to atmosphere by the heat dump radiators, the intercooler cooling system is used to provide cooling to the engine lubricating oil system, valves are provided on the jacket water cooling, and lubricating oil systems to enable future connections to a second heat recovery system

Voltage: 11,000. Cycle: 50. Phase: 3. Operational Hours: 34,000. Drive Power: 4,650 kW (6,250 HP). Fuel Type: Natural Gas. Powered By: Engine. Controls: Yes.