Start with the equipment family, narrow into the right subtype, and compare available inventory using search terms, manufacturers, materials, and technical filters.
Choose whether you want to browse equipment, complete systems, or entire plants before narrowing the results.
Move between closely related subtypes without leaving the current equipment family.
These filters are based on the selected equipment category and subtype, so you can narrow the listings using the attributes that matter for this type of asset.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Enter a keyword to match this specification.
These options come from the current listings and highlight the manufacturers, materials, and other attributes most common in this equipment set.
Showing 8 of 8 matching Shell and Tube.
tube pressure rated by -1/10bar @-10/200 degrees C (volume 66 liter), shell pressure rated by -1/10bar @ -10/200 degrees C (volume 180 liter) Length: 4,800 mm. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 14 mm. Tube Length: 4,200 mm. Tube Thickness: 1.5 mm. Nozzle Schedule: shell side: (1) DN100, (2) DN200, (1) DN300; tube side: (1) DN150, (1) DN200. Capacity: 246 L. Heat Exchanger Tube Capacity: 66 L.
Design pressure tube side -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, heat exchanger in 2 x sections, 2-reduction heads, tube material is silicon carbide (SiC) Length: 189 in. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 151. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
design pressure tube side -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, Length: 189 in. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
design pressure -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, tube material is silicon carbide (SiC); Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 151. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
tube material is silicon carbide (SiC) Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
design pressure -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, tube material is silicon carbide (SiC); Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
design pressure tube side -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, tube material is silicon carbide (SiC) Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (2) DN150;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
design pressure tube side -1/10 bar @ -10/200 degrees C, shell side -1/10 bar @ -10/200 degrees C, CE0035, 2 x clamped sections, tube material is silicon carbide (SiC) Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 151. Tube Diameter: 0.55 in. Tube Length: 157.5 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube side: (2) DN150; shell side: (1) DN100, (2) DN200, (1) DN300;. Capacity: 47.6 gallons. Heat Exchanger Tube Capacity: 17.4 gallons.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.