Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Highest-ranked available inventory for this selection.
Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Enter a keyword to match this specification.
Showing 25 of 708 matching Shell and Tube.
tube pressure rated by -1/10bar @-10/200 degrees C (volume 66 liter), shell pressure rated by -1/10bar @ -10/200 degrees C (volume 180 liter) Length: 4,800 mm. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 14 mm. Tube Length: 4,200 mm. Tube Thickness: 1.5 mm. Nozzle Schedule: shell side: (1) DN100, (2) DN200, (1) DN300; tube side: (1) DN150, (1) DN200. Capacity: 246 L. Heat Exchanger Tube Capacity: 66 L.
Rated FV/300 psi @ -20 to 425 degrees tube side; FV/50 psi @ -20 to 425 degrees F shell side.
with glass lined clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
AL6XN channel heads with R-Stamp(1994) Tube Diameter: 1.25 in. Tube Length: 144 in. Tube Thickness: 0.02 in. Nozzle Schedule: - Nozzle Schedule: - Two 32" tube side nozzles (brine inlet & outlet) - One 18" steam inlet - One 4" condensate outlet - One 3" drain - Two 1" drain/vents.
heat exchanger (steam chest) Length: 204 in. Tube Type: Straight Tube. Tube Number: 189. Tube Diameter: 2 in. Tube Thickness: 0.06 in. Nozzle Schedule: Steam inlet nozzle, 8", condensate nozzle 3", Vapor nozzle 22", circulation nozzle 8".
Rated 300/FV @ -20 to 425 degrees tube side; FV/50 psi @- 20 to 425 degrees F shell side. clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
15.25" diameter x 1.5" thick. (2) Hastelloy B heads. Alloy 600 expansion joint n the shell. Length: 237 in. Tube Number: 64. Tube Diameter: 1 in. Tube Length: 237 in. Tube Thickness: 0.06 in. Nozzle Schedule: Openings include Tube side: (2) 6"; shell side (1) 4"; (1) 2". .
Poly Silicone shell and tube heat exchanger
301 SS tubes, 301 SS tube sheet, 321 SS welded dish heads Tube-side Passes: 3. Tube Type: Straight Tube. Tube Number: 292. Tube Diameter: 0.75 in. Tube Length: 132.8 in. Tube Thickness: 0.06 in. Nozzle Schedule: Tube nozzles are 6", shell side nozzles are one 18" and two 2".
Size 25-C-72 with CS tubes sheet 1 1/2" thick (2) CS heads Tube Diameter: 0.75 in. Tube Length: 168 in. Tube Thickness: 0.04 in.
Rated 150/FV @ -20 to 400 degrees F tube side 150/FV @ -20 to 400 degrees F Shell Side Unit has (2) bolted flat heads (1) Tanalum, (1) CS with tantalum lining Length: 94.5 in. Tube Number: 84. Tube Diameter: 0.75 in. Tube Length: 72 in. Nozzle Schedule: - Nozzles: Shell side has two 4" nozzles with 1" reducing flanges - Inlet/outlet: Tube side inlet is 4", tube side outlet is 3" with a 1" drain..
One fixed head, one floating head design
TEMA type: BFM, size 26-288 Vent & Drain: Two 3/4" Shell-side Passes: 2. Tube-side Passes: 2. Tube Type: Straight Tube. Tube Number: 360. Tube Diameter: 0.75 in. Tube Length: 288 in. Tube Thickness: 0.06 in. Nozzle Schedule: Nozzles: 2-8" shell side nozzles, 2-4" tube side nozzles.
kettle type reboiler U tube bundle is 12" diameter x 16' 11" straight side. 403 " long total length around the bend (1) CS bolted dished head for tube bundle Carbon Steel Kettle type re-boiler shell 280" over all length. Tube Type: U-Tube. Tube Number: 22. Tube Diameter: 1 in. Tube Length: 203 in. Tube Thickness: 0.08 in. Nozzle Schedule: Openings: Tube side - (1) 3" inlet, (1) 1" outlet; Shell side - (1) 6" inlet, (1) 8" vapor outlet, (1) 2" liquid outlet.
Flash condenser
No NB number Length: 96 in. Tube-side Passes: 12. Tube Number: 562. Tube Diameter: 0.75 in. Tube Thickness: 0.04 in. Nozzle Schedule: Openings include: (1) 10"; (1) 4"; One head (2) 3"; Other head - (1) 1'..
Size 19-B-156 With CS tubes sheet 1 3/4" thick (2) CS Channel heads Tube Diameter: 0.75 in. Tube Length: 150 in. Tube Thickness: 0.04 in. Nozzle Schedule: Openings: Tube Side - (2) 12", (2) 1.5" drains; Shell side - (2) 6", (2) 1.5".
CRN #: K5721.5
OIN #: 5.882.524
Baffles: (20) CS 3/16" thick
Channel heads: (2) 316LSS, 3/16" thick
with expansion joint
with (20) CS 3/16" thick baffles. Tube Number: 462. Tube Diameter: 1 in. Tube Length: 240 in. Tube Thickness: 0.06 in. Nozzle Schedule: - Openings: Shell side - (2) 4"; One Head - (1) 16"; other head (2)6"..
Job #: 161730 Tube Diameter: 0.75 in. Tube Thickness: 0.06 in. Nozzle Schedule: - Shell side nozzles: two 4" with 1" vents and drains - Tube side nozzles: 2" and 1.5" with 1/2 " vent and drains.. Capacity: 150 gallons.
Shell is rated for MAWP, 225 psi at 450 degrees F. Shell MDMT is -20 degrees F. at 225 psi. Tubes are rated for MAWP 150 psi at 450 degrees F Tubes MDMT is rated for -20 degrees F. at 150 psi Shell side inlet and outlet are 3" threaded. Tube side inlet and outlet are 2" threaded.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.