Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Highest-ranked available inventory for this selection.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Enter a keyword to match this specification.
Showing 25 of 33 matching Shell and Tube.
condenser Tube dimensions: 20 mm x 32mm OD x 1740 mm long Tube Length: 1,750 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: (2) 50 mm tube side; (2) 100 mm, (1) 25mm Shell side.
condenser Tube Dimensions: 20mm x 32mm OD x 2940mm long Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: - Tube Side: 2-100mm - Shell Side: 2-100mm, 1-40mm.
condenser Tube dimensions: 20 mm x 32mm OD x 1740 mm long Tube Length: 1,750 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: (2) 150 mm, (1) 50mm tube side; (2) 100 mm, (1) 25mm Shell side.
condenser pressure shell side rated -1/10 bar @ -25/200 degrees C (volume 350 liter), pressure tube side rated -1/5 bar @ -28/200 degrees C (volume 204 liter), Tube Thickness: 5 mm. Nozzle Schedule: openings tube side (1) DN50, (1) DN150, (1) DN250, openings shell side (1) DN25, (2) DN150.
condenser Tube dimensions: 20 mm x 32 mm OD x 2940 mm long Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: Shell openings: (2) 100 mm tube side; (2) 100 mm, (1) 40 mm shell side.
condenser Tube dimensions: 20mm x 32mm OD x 2940mm long Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: - Tube side: (2) 100 mm - Shell side: (2) 100 mm, (1) 40mm.
condenser pressure shell side rated 6 bar @ 165 degrees C (volume 107 liter), pressure tube side rated 6 bar @ 165 degrees C (volume 36 liter) Nozzle Schedule: openings tube side (2) DN100, (1) DN40, openings shell side (2) DN100, (1) DN40,.
Tube Dimensions: 20 mm ID x 32 mm OD x 2985 mm long
Graphite Tube / CS Shell vertical condenser,
Shell Volume: 213 liters Tube Volume: 81 liters Tube Dimensions: (60) 7/8" ID/1 1/4" OD x 2985 mm long Tube Length: 3,000 mm. Tube Thickness: 0.37 in. Nozzle Schedule: - Openings: Tube side (2) 150mm; Shell side (2) 100mm.
condenser Tube dimensions: (24) 20mm x 32mm OD x 1790mm long Tube Diameter: 32 mm. Tube Length: 1,800 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: 1-head with 2-50mm, 1-head with 1-100mm, shell: 2-100mm, 1-25mm.
falling film condenser With weirs on top of tubes rated 6 bar @ 200 degrees C Service Side; 6 bar @ 200 degrees C process side. Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: Tube Side Openings: (2) 100 mm - Shell Side Openings: (2) 100 mm, (1) 40mm.
condenser Tube dimensions: 20 mm x 32 mm OD x 2940 mm long Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Openings: (2) 100 mm tube side; (2) 100 mm, (1) 40 mm shell side.
condenser Tube dimensions: 20 mm x 32mm OD x 2940 mm long Tube Length: 2,950 mm. Tube Thickness: 12 mm. Nozzle Schedule: - Tube side openings: (2) 100 mm - Shell side openings: (2) 100 mm, (1) 40mm.
design pressure process side 7 bar @ 50/61 degrees C, service 3.6 bar @ 23/34 degrees C, exchanger made up of 8- blocks of HP2/20 elements
condenser
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.