pressure both sides -1/10 bar @ -50/150 degrees C (18 liter/17 liter)
fully insulated, CE-0036,
Process sidde rated 45 PSI @ -30/+122 degrees F.
Service side rated 30 PSI @ -30/+122 degrees F.
pressure side A -1 /10 bar @ -10/200 degrees C (2.06 liter) side B -1/10 bar @ -10/200 degrees C (2.33 liter),
fully insulated
2-pass both sides
Welded plate heat exchanger type
with 316TiSS wetted parts
horizontal design
reference number 6121B
Process side rated 2 bar @ 150 °C design pressure, 0.5 bar
19 dm3 capacity; service side rated 2 bar @ 100 °C, 43 dm3 capacity.
All wetted parts are material Z2CND 17-12 France standard, (3156TiSS).
Empty weight 410 Kg.
Vertical thermo panel bank condenser / heat exchanger (plate pack in a cylindrical shell)
Pressure plate side: 10 bar @ 110 degrees C (190 liter)
Shell side: 10 bar @ 250 degrees C (2700 liter)
(38) 316L (1.4404) stainless steel Thermo plates,
Free space: 10mm
Spot pattern: 47 x 31.25mm
316L (1.4404) stainless steel shell,
weld dished heads
Vertical thermo panel bank condenser / heat exchanger (plate pack in a cylindrical shell)
Pressure plate side: 10 bar @ 110 degrees C (12 liter)
Shell side: 10 bar @ 250 degrees C (85 liter)
(12) 316L (1.4404) stainless steel Thermo plates,
316L (1.4404) stainless steel shell,
weld dished heads,
150kw
pressure on both sides -1 /10 bar @ -15/160 degrees C (6/6.3 liter),
CE0035 certified
pressure both sides -1/10 bar @ -30/150 degrees C (3 liter/4 liter)
CE0409,
fully insulated,
Titanium/321 (1.4401) stainless steel plate heat exchanger,
pressure side 1 -1/6 bar @ -20/150 degrees C (32 liter), side 2 -1/6 bar @ -20/150 degrees C (33 liter),
plate material side 1 321 (1.4401) stainless steel, side 2 Titanium,
pressure both sides -1/6 bar @ -10/200/150 degrees C (16/16 liter)
Ti s/steel plates
Passes: 2-pass both sides
maximum temperature is 410 degrees F
Minimal design metal temp.=-20 degrees F at 200 psi.
Minimal design metal temp.=-20 degrees F at 200 psi.
2-pass both sides
Maximum temperature 410 degrees F
gasketed plates.
welded plate heat exchanger
with 316TiSS wetted parts
horizontal design
0.7 bar working pressure 90 dm3 capacity
125 dm3 capacity
All wetted parts are material Z2CND 17-12 France standard, (3156TiSS)
The rectangular housing is 260 mm wide, 3200 mm long
Empty weight 1200 Kg
pressure on both sides -1/10 bar @ -10/200 degrees C (2.9/3.2 liter)
150kw
fully insulated,
Type: V60.SST.A
carbon steel frame
Chilled water service
Size unknown,
insulated
316 SS plates with CS frame,
rated for 199585 lbs./hr. water
and 210539 lbs./hr. glycol.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.