Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Highest-ranked available inventory for this selection.
Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Enter a keyword to match this specification.
Showing 25 of 707 matching Shell and Tube Heat Exchangers.
tube pressure rated by -1/10bar @-10/200 degrees C (volume 66 liter), shell pressure rated by -1/10bar @ -10/200 degrees C (volume 180 liter). Tubes alpha silicon carbide. Length: 4,800 mm. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 14 mm. Tube Length: 4,200 mm. Tube Thickness: 1.5 mm. Nozzle Schedule: shell side: (1) DN100, (2) DN200, (1) DN300; tube side: (1) DN150, (1) DN200. Capacity: 246 L. Heat Exchanger Tube Capacity: 66 L.
Rated FV/300 psi @ -20 to 425 degrees tube side; FV/50 psi @ -20 to 425 degrees F shell side.
with glass lined clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
AL6XN channel heads with R-Stamp(1994) Tube Diameter: 1.25 in. Tube Length: 144 in. Tube Thickness: 0.02 in. Nozzle Schedule: - Nozzle Schedule: - Two 32" tube side nozzles (brine inlet & outlet) - One 18" steam inlet - One 4" condensate outlet - One 3" drain - Two 1" drain/vents.
31m² tantalum tube carbon steel shell, horizontal shell and tube heat exchanger, manufactured by Tantec, serial number 4278, tube pressure rated by -1/6bar @-10/200 degrees C (volume 100 liter), shell pressure rated by -1/8bar @ -10/200 degrees C (volume403 liter), carbon steel shell 490mm diameter x 4508mm length, (175) tubes 12.7mm diameter x 0.4mm thickness x 4.500mm length, openings shell side: (1)DN100, (1)DN250; openings tubeside: (2)DN150, mounted on 2 saddles Length: 4,500 mm. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 175. Tube Diameter: 12.7 mm. Tube Length: 4,500 mm. Tube Thickness: 0.4 mm. Nozzle Schedule: shell side: (1)DN100, (1)DN250; tubeside: (2)DN150. Capacity: 503 L. Heat Exchanger Tube Capacity: 100 L.
kettle type reboiler With SS U-tube bundle
Type BEM. Replacement shell, spare, no heads with the unit. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 135. Tube Diameter: 0.75 in. Tube Length: 140.8 in. Tube Thickness: 0.08 mm. Nozzle Schedule: 3" outlet, 10" inlet, (2) 3/4", 3/4" vent, 3/4" drain..
and two 1" vent/drains Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.75 in. Tube Length: 48 in. Tube Thickness: 0.01 in. Nozzle Schedule: shell side has two 4" nozzles, Bottom Bonnet has two 3" nozzles, top has one 8" nozzle.
kettle type reboiler U tube bundle is 12" diameter x 16' 11" straight side. 403 " long total length around the bend (1) CS bolted dished head for tube bundle Carbon Steel Kettle type re-boiler shell 280" over all length. Tube Type: U-Tube. Tube Number: 22. Tube Diameter: 1 in. Tube Length: 203 in. Tube Thickness: 0.08 in. Nozzle Schedule: Openings: Tube side - (1) 3" inlet, (1) 1" outlet; Shell side - (1) 6" inlet, (1) 8" vapor outlet, (1) 2" liquid outlet.
(48) 1" OD welded tubes. (2) Glass lined heads. Tube Diameter: 1 in.
Tantalum clad heads 18" diameter x 75.25" Overall length. (face to face 48") Length: 75.3 in. Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.7 in. Tube Length: 48 in. Tube Thickness: 0.015 in. Nozzle Schedule: Shell side - two 4", Tube side - one 8" and two 3"..
approx 8 square meter 316L stainless steel 'U' tube, head and shell horizontal heat exchanger, manufactured by E.Prang & Co Apparatebau, type WT 26.0-ZN-547, fabrik #453.5.5, design pressure tube side: 10 bar @ 120 degrees C (134.5 liter), shell 10 bar @ 300 degrees C (115.5 liter), 316L stainless steel tubes, 316L stainless steel tube sheets, 316L stainless steel shell, (1) 316L stainless steel flat bonnet head, mounted on 2-saddles, Capacity: 30.5 gallons. Heat Exchanger Tube Capacity: 35.5 gallons.
Tube Type: Straight Tube. Tube Number: 436. Tube Diameter: 0.75 in. Tube Length: 144 in. Tube Thickness: 0.08 in. Nozzle Schedule: 3" 6" 12".
Tubes rated FV Length: 23.9 in. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 55. Tube Diameter: 0.75 in. Tube Length: 23.9 in. Tube Thickness: 0.05 in. Nozzle Schedule: Two 2", two 1.5".
working pressure tube side 7.5 barg (0.75 Mpa) @ 50 degrees C (350 liter ), shell side 53 barg (5.3 Mpa) @ 95 degrees C (450 liter) (1) carbon steel bonnet head, (1) carbon steel tubesheet, design code: CODAP 95 A f2, Tube-side Passes: 4. Tube Type: U-Tube. Tube Number: 186. Tube Diameter: 19.1 mm. Tube Length: 2,250 mm. Tube Thickness: 2.1 mm. Nozzle Schedule: openings tube side: bonnet head with 2-100mm, shell: 2-100mm, 2-50mm, .
pressure tube side: -1/84 bar @ -10/250 deg C (371 liter), shell side -1/25 bar @ -10/250 deg C (442 liter) (2) 321 (1.4541) stainless steel heads Tube Number: 211. Tube Diameter: 25 mm. Tube Length: 2,500 mm. Tube Thickness: 2 mm. Nozzle Schedule: - Head openings: (2) heads: DN250/PN160, (1) DN300/PN40, (1) DN200/PN40, (2) DN150/PN40.
condenser 1' NPT vent/drain Nozzle Schedule: Openings include: Two shell openings inlet and outlet are 4". Vapor head, has one 8" nozzle, Discharge head has one offset 6" nozzle. .
Rated 300/FV @ -20 to 425 degrees tube side; FV/50 psi @- 20 to 425 degrees F shell side. clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.