Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Highest-ranked available inventory for this selection.
Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Enter a keyword to match this specification.
Showing 25 of 709 matching Shell and Tube Heat Exchangers.
tube pressure rated by -1/10bar @-10/200 degrees C (volume 66 liter), shell pressure rated by -1/10bar @ -10/200 degrees C (volume 180 liter) Length: 4,800 mm. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 14 mm. Tube Length: 4,200 mm. Tube Thickness: 1.5 mm. Nozzle Schedule: shell side: (1) DN100, (2) DN200, (1) DN300; tube side: (1) DN150, (1) DN200. Capacity: 246 L. Heat Exchanger Tube Capacity: 66 L.
Rated FV/300 psi @ -20 to 425 degrees tube side; FV/50 psi @ -20 to 425 degrees F shell side.
with glass lined clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
AL6XN channel heads with R-Stamp(1994) Tube Diameter: 1.25 in. Tube Length: 144 in. Tube Thickness: 0.02 in. Nozzle Schedule: - Nozzle Schedule: - Two 32" tube side nozzles (brine inlet & outlet) - One 18" steam inlet - One 4" condensate outlet - One 3" drain - Two 1" drain/vents.
Rated 150 psi @ -20 to 450 degrees F tube side, 225 psi @ -20 to 450 degrees F shell side. Tube Number: 210. Tube Diameter: 0.37 in. Nozzle Schedule: Inlet and outlet are 2" threaded. Shell side nozzles are 3" threaded..
Tubes rated FV Length: 23.9 in. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 55. Tube Diameter: 0.75 in. Tube Length: 23.9 in. Tube Thickness: 0.05 in. Nozzle Schedule: Two 2", two 1.5".
surface condensor Certified by Allyn American
and two 1" vent/drains Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.75 in. Tube Length: 48 in. Tube Thickness: 0.01 in. Nozzle Schedule: shell side has two 4" nozzles, Bottom Bonnet has two 3" nozzles, top has one 8" nozzle.
Flash condenser
approx 24.8 square meter, design pressure tube side 2 bar + vacuum @ 247 degrees C, shell 36 bar @ 247 degrees C, top head is a right angled pipe, bottom head is bolt cone reducer, Length: 2,000 mm. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 228. Tube Diameter: 0.75 in. Tube Length: 78.7 in. Capacity: 121.5 gallons. Heat Exchanger Tube Capacity: 56.3 gallons.
Shell is rated for MAWP, 225 psi at 450 degrees F. Shell MDMT is -20 degrees F. at 225 psi. Tubes are rated for MAWP 150 psi at 450 degrees F Tubes MDMT is rated for -20 degrees F. at 150 psi Shell side inlet and outlet are 3" threaded. Tube side inlet and outlet are 2" threaded.
approx 46 square meter, shell with expansion bellows, approx 3.2m long tubes Tube Number: 246. Tube Diameter: 0.75 in. Tube Length: 0.13 in. Capacity: 125.5 gallons. Heat Exchanger Tube Capacity: 77.4 gallons.
approx 30 square meter, tubes approx 2.2m long, Capacity: 150.6 gallons. Heat Exchanger Tube Capacity: 55.5 gallons.
Tantalum clad heads 18" diameter x 75.25" Overall length. (face to face 48") Length: 75.3 in. Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.7 in. Tube Length: 48 in. Tube Thickness: 0.015 in. Nozzle Schedule: Shell side - two 4", Tube side - one 8" and two 3"..
304L SS with Hastelloy C clad tube sheet Hastelloy lined CS shell Length: 60 in. Tube Type: Straight Tube. Tube Number: 333. Tube Diameter: 0.75 in. Tube Length: 26 in. Tube Thickness: 0.03 in. Nozzle Schedule: One 8" nozzle, One 4" nozzle, three 3" nozzles. .
Internals are 25 Ra electropolished. External as welded and passivated Inner and outer tube sheets are removable hell inlet and outlets are 8" RFSO flange, Tube inlet/outlet are 3" WE. Two 3/4" couplings for the vents & drain. Length: 88 in. Shell-side Passes: 4. Tube-side Passes: 4. Tube Type: U-Tube. Tube Number: 172. Tube Diameter: 0.5 in. Tube Length: 84 in. Tube Thickness: 0.04 in.
Heads: Cast Iron Part #: 5-162-06-036-046 Two pass' Tube Number: 116. Tube Diameter: 0.37 in. Tube Thickness: 0.02 in. Nozzle Schedule: - Nozzles: 2" on shell and heads..
approx 38 square meter pressure shell side 4 bar + vacuum @ 191 degrees C, tube side 2.5 bar @ 191 degrees C, Length: 130.1 in. Tube Type: Straight Tube. Tube Number: 228. Tube Diameter: 1.01 in. Tube Length: 86.6 in. Capacity: 134.7 gallons. Heat Exchanger Tube Capacity: 55.5 gallons.
CE0036 design pressure tubeside -1/6 bar @ -30/200 degrees C (132 liter), shell -1/12 bar @ -30/200 degrees C (85 liter) shell with expansion bellows (2) Hastelloy C22 integral channel heads with bolt flat end plate (14) 316L stainless steel internal baffle plates Length: 2,500 mm. Tube Type: Straight Tube. Tube Number: 58. Tube Diameter: 24.4 mm. Tube Length: 1,800 mm. Tube Thickness: 1.6 mm. Nozzle Schedule: openings: 1-head with 150mm, 1-head with 1-75mm, 1-32mm, shell: 2-50mm. Capacity: 57.3 gallons. Heat Exchanger Tube Capacity: 34.9 gallons.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.