3-pass wet back furnace tube deisgn and oil fired, Manufacturer: Hamworthy Combustion, Type: SG5/1900 automatic gas fuel, boiler has an economiser, design pressure 110psig, deisgn code BS2790:1989, class 1, (2) feed water pumps, total weight= 7625kg
normal working pressure 83 bara, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or gas oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, energy input 13.1 MW, fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78sqm, total 881sqm the boiler is an all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, boiler includes: (1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends, (1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar, (1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara (3) Feed water pumps, manufactured by KSB, type HGM-2/15, Other associated equipment include fans, valves, pumps, instruments, control panels, etc
electronic intermittent pilot ignition Surface heating area, 83.4 Sq. Ft. Gas connection is 1.25", water inlet and outlet are 2", and pressure relief line is 1" Flue size is 12".
Built in Economizer.
This boiler can fire on Natural Gas or Light Oil , however, in the previous application they were only burning gas, so there are no accessories to burn the light oil. 04/25/24 Per Miller & Chitty Manufacturer weight is 36,000 LBS. (RP)
normal working pressure 83 bara, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or gas oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, energy input 13.1 MW, fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78sqm, total 881sqm the boiler is an all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, boiler includes: (1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends, (1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar, (1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara (3) Feed water pumps, manufactured by KSB, type HGM-2/15, Other associated equipment include fans, valves, pumps, instruments, control panels, etc
and gas oil fired energy input 13.1 MW fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78 SqM, total 881 SqM. 2 x 20 t/hr boilers working in tandem, the boilers are all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, final condensing (Ceecon) economiser which preheats the boiler feed water. Main item consists of: (2) 20 t/hr (design load, 100% Maximum Continuous Rating) Ansaldo Volund water tube boilers, design pressure 91 bara, normal working pressure 83 bara, feed water temperature 105 deg C, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, (1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends, (1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar, (1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara (3) Feed water pumps, manufactured by KSB, type HGM-2/15, Other associated equipment include fans, valves, pumps, instruments, control panels, platform between boilers, etc
Unit number: W-3525 Boiler heating surface sq. ft. 1517, Water wall sq. ft. 302 Max 20.574, Main Power 460 volts. Shipping dimensions 11’ wide x 25’ long x 12’ 6” min. to 13’ 4 “ max. overall height.
(2) tank Dearator system
Feed Pac type
with (2) 800 gallon tanks
SO # 00-529-S.
800 gallon tank capacity
driven by 15HP Baldor motors .
With BFS Industries system controls.
design saturated steam temperature 188 degrees C (@ 10.5 barg), safety valve setting 11.55 barg, heat transfer duty 2934 +- 15%, specific garavity/density 0.95 kg/m3, specific heat 1.00 kCal/kg.C boiler an with economiser, manufactured by Flametec ltd, serial #35690/04068, design pressure 20 barg @ 160 degrees C,
Spraymaster Dearator 14 GPM Total Boiler HP 203
medium pressure electric boiler 3.47 BHP 34 kW requires 208/240/480 volts Features Water feed controls and Low water cut off, High Pressure limiter steam pressure gauges water level sight glass Drain and blow down valves
Fireside heating surface area is 750 sq.ft
Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8
Safety valve rated for 6000 psi
Boiler has 182, two-inch tubes
This boiler features FGR and low Nox operation with its IRI gas train
While firing natural gas, emissions levels are no greater than 30 PPM of NO x
Water requirements are 6551 pounds of water or 785 gallons
Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
Fireside heating surface area is 750 sq.ft
Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8
Safety valve rated for 6000 psi
Boiler has 182, two-inch tubes
This boiler features FGR and low Nox operation with its IRI gas train
While firing natural gas, emissions levels are no greater than 30 PPM of NO x
Water requirements are 6551 pounds of water or 785 gallons
Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
Fireside heating surface area is 750 sq.ft
Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8
Safety valve rated for 6000 psi
Boiler has 182, two-inch tubes
This boiler features FGR and low Nox operation with its IRI gas train
While firing natural gas, emissions levels are no greater than 30 PPM of NO x
Water requirements are 6551 pounds of water or 785 gallons
Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
Fireside heating surface area is 750 sq.ft
Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8
Safety valve rated for 6000 psi
Boiler has 182, two-inch tubes
This boiler features FGR and low Nox operation with its IRI gas train
While firing natural gas, emissions levels are no greater than 30 PPM of NO x
Water requirements are 6551 pounds of water or 785 gallons
Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
Fireside heating surface area is 750 sq.ft
Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8
Safety valve rated for 6000 psi
Boiler has 182, two-inch tubes
This boiler features FGR and low Nox operation with its IRI gas train
While firing natural gas, emissions levels are no greater than 30 PPM of NO x
Water requirements are 6551 pounds of water or 785 gallons
Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
When your process demands reliable steam or hot water generation for heating, power, or production, industrial boilers provide critical support across industries. With more than 47 years of experience, IPP offers immediate access to used boilers sourced from 20 complete plant sites and included in our inventory of over 15,000 ready-to-ship pieces of equipment. Buying used boilers from IPP helps companies reduce capital costs, avoid long lead times, and maintain reliable energy production.
Boilers generate steam or hot water by heating water through combustion or electric elements. They are essential for a wide range of applications, including process heating, power generation, sanitation, and HVAC support. Available boiler types include fire-tube, water-tube, hot oil heaters, waste heat recovery boilers, and electric boilers.
Boilers are built to withstand high pressure and temperature cycles, with construction based on application needs:
Search the IPP inventory or contact IPP’s equipment specialists to secure a used boiler tailored to your process heating needs. With ready-to-ship inventory, IPP helps companies avoid supply chain delays, manage project costs, and ensure dependable steam or hot water production.
Have questions about Boilers or our services? Learn more about our products and why customers choose IPP.