Used turbines for sale – power generation and mechanical drive systems for industrial use IPP stocks used, secondhand, and surplus turbines ready to support chemical, utility, and processing plants Increase plant efficiency with ready-to-ship turbines from IPP’s global inventory {{Featured}}
Highest-ranked available inventory for this selection.
Enter a keyword to match this specification.
Use this setting to include or exclude equipment with this feature.
Set a numeric threshold to narrow the matching listings.
Use this setting to include or exclude equipment with this feature.
Use this setting to include or exclude equipment with this feature.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Use this setting to include or exclude equipment with this feature.
Showing 20 of 20 matching Steam.
Steam turbine originally designed to be used to drive a compressor, but can be used to drive other machines.
Dresser Rand Series ET-186, Five Rateau stages. Normal speed is 6540 rpm, max. speed is 6760 rpm. First critical speed is 2900 rpm, second critical speed is 7800 rpm. Speed regulation is by a Woodward governor, model 505E.
The turbine has the following alarms/shutdowns; Over speed, Emergency valve, solenoid valve, Low oil pressure, and high input steam pressure.
Requires 63 gpm cooling water for oil cooler. Complete pressurized oil system operating at 116 psig. Size of turbine alone is 9’ x 6’ x 7’ at 14,000 lbs.
multi valvesingle row, solid rotorCasing is manufactured from a Chrome Molly Alloy, with a forged Shaft."Engineering solution" Single stageSpecial 13,506 rpm, rated 1150 psi steam @ 890 deg F,550 psi exhaustIncludes spare rotor and parts
multi valve , single row, solid rotor, backpressure design. Casing is manufactured from a Chrome Molly Alloy, with a forged Shaft. "Engineering solution" Single stage. Special 13,506 rpm, rated 1150 psi steam @ 890 deg F, 550 psi exhaust. Includes spare parts.
50 Cycle, steam turbine generator set, with extraction. Extraction 1: non controlled 2800 kg/h max, Extraction 2: controlled 27000 kg/h, pressure: 11-14 kp/cm² ( 156-199 psi) with 7.150 PS MAAG gearbox, 6614/3000 rpm, order # 714321A G-40 spez. steam turbine weight 16.000kg. System included a generator MFO 56420 K01.1, type 14 S 250, 6600 KVA , COS Phi 0.8, Voltage: 11 kV, 50 Hz, 3.000 rpm, generator weight 19.000 kg. (1) causative agent MFO 564420 K03.1, type R 841, Voltage: 70 kW/165V. (2) 3.6 ltr/sec GEA air-cooled water-cooler, type 6425/320/32-NSV-S119-32D182, order # 104/13785, rated 10 bar, volume 9.5 ltr. (1) 12.2 m² Oil cooler, type EW, 1.200mm long with (216) pipes 15mm diameter x 1mm thickness , material of pipes (SoMs 71) brass, rated @ 45 degrees C normal, @ 50 degrees C max with Oil tank inhold 2.800 liter, Oil tank weight 2.000kg. (1) 500 ltr/min main oil pump, type ALG 60-4, rated 7 kp/cm² eff. (1) 500 ltr/min Auxiliary electrical pump, type 60-3N7K, rated 7 kp/cm² eff. (1) 24 m² c/steel shell vertical preheater, type EW, 5.300mm long with (96) pipes 15mm diameter x 1mm thickness , material of pipes (SoMs 71) brass. (with) different valves, controls and c/steel pipes. SEE PLANT INVENTORY FOR MORE INFO.
Single cylinder extraction backpressure of Axial flow type, extraction steam 205 psi (14.2 bar),Steam consumption 130 ton/hr.
Cast Iron Non-Condensing turbine mounted Horizontally Inlet nozzle is 6" mounted on the side Exhaust pressure is 55 psi exhaust nozzle is 12" and mounted up Designed to drive compressor IPPE # 207980.
back pressure turbine.steam consumption 13.2 lb/BHP/hr,Total flow 106900 lbs/hr.
condensing turbine SO number U-14351 ( double flow on 4th & 5Th stage) HG. ABS. at 128 degrees F 12" inlet nozzle. Rotation clockwise.
back pressure turbine. steam consumption 13.2 lb/BHP/hr Total flow 106900 lbs/hr.
back pressure turbine, steam consumption 13.55 lb/BHP/hr, inlet temp normal 940 deg F, inlet temp max 965 deg F, Total flow 148200 lbs/hr.
back pressure turbine. steam consumption 13.55 lb/BHP/hr, Total flow 148200 lbs/hr.
condensing turbine. inlet pressure normal 190 psig steam consumption 9.9 lb/BHP/hr, Total flow 83000 lbs/hr.
Order #U-19182 6435 trip speed. Frame S5, 2nd critical rpm 11,500. Includes a spare rotor. (NOTE: Used to drive a gas compressor, see IPP# 222927 for full compressor).
counter clockwise rotation
Spare rotor for steam turbine stock # 701561 Manufactured from a forged blank of Alloy, containing impulse blades, reaction blades, and moving blades.
Used turbines remain a core component of industrial energy systems, converting thermal or fluid energy into mechanical motion or electrical power. Whether you’re looking to support a cogeneration system, back up steam recovery, or replace a failed driver, IPP provides inspected, in-stock turbine systems from 20 global plant sites. With over 47 years of experience, IPP is the world’s largest supplier of used process equipment, with more than 15,000 systems in stock — including steam turbines, gas turbines, and mechanical drives.
IPP’s inventory includes backpressure turbines, condensing turbines, and mechanical drive turbines from trusted OEMs such as GE, Dresser-Rand, Siemens, Elliott, and Peter Brotherhood.
Learn more about how turbines are used in process industries via Power Engineering.
Have questions about Turbines or our services? Learn more about our products and why customers choose IPP.